E300 Operation Manual
Alarm List
Document Version: V1.01
ESTUN AUTOMATION Proprietary
XII
No. Alarm Name Cause Solution Remove
A.32 Mode Err
No mode signal or both the
Single and JOG signals become
effective at the same time.
Check whether the signals of Single and Jog
is properly wired and allocated.
Manual
A.33 Mode_OPT_Err
Switch the operation mode
when the machine was running.
This fault message will be displayed, and the
machine stops right now.
Automatic
A.35 Communication Err
In the non-initialized state, the
internal communication of the
device is interrupted.
Contact ESTUN. Manual
A.36 X-axis Lost
The system has no
communication with the servo
drive of X-axis.
Check the servodrive of X-axis and Check
whether the CAN communication port is
disconnected.
Manual
A.37 Y-axis Lost
The system has no
communication with the servo
drive of Y-axis.
Check the servodrive of Y-axis and Check
whether the CAN communication port is
disconnected.
Manual
A.38 R-axis Lost
The system has no
communication with the servo
drive of R-axis.
Check the servodrive of R-axis and Check
whether the CAN communication port is
disconnected.
Manual
A.39 Can Send Err. Send the data by CAN failed.
Check whether the CAN communication port
is disconnected.
Manual
A.40 Drive Para. Err.
The setting of parameter Servo
ID is incorrect.
Modify the Servo ID and then press Clear to
reset the alarm.
Manual
A.41 X-axis Err The servo s in the alarm state. See the servo user manual. Manual
A.42 Y-axis Err The servo is in the alarm state. See the servo user manual. Manual
A.43 R-axis Err The servo is in the alarm state. See the servo user manual. Manual
A.51 DIO port Err The port allocation is incorrect. Check and renumber the port allocation. Manual
A.52 System locked
The license of the device is
incorrect.
Contact ESTUN or manufacturer. Manual
A.53 Power Off
The power supply is lower than
the rated value.
Manual
A.60 DRV Err Code 2310 Overcurrent See the servo user manual. Manual
A.61 DRV Err Code 3100
The servo was instantaneous
outage.
See the servo user manual. Manual
A.62 DRV Err Code 3110 Overvoltage See the servo user manual. Manual
A.63 DRV Err Code 3120 Under voltage See the servo user manual. Manual