Loading...
E300 Operation Manual
Programming
Document Version: V1.01
ESTUN AUTOMATION Proprietary
2-1
Chapter 2 Programming
2.1 Page Structure
Power up the device and wait for a while, the screen can display the initial page (Single-Step)
automatically, as shown in Figure 2-1.
SingleStep Not Ready Stop
Y: 0
.
00
Die = 1 Y-axis = 0
.
00 mm
Material = 1 X-axis = 0.00 mm
Thickness = 0.100 mm
Hold Time = 1.00 s
Retr.DLY = 0.50 s
Retract = 0.00 mm
Angle = 150.00 °
Corr.
α = 0
.00 °
Stock = 50
Single Multi Manual Die Program Constant
Range [0 ,30 ] 12: 00
X: 0.00
CP:
1
*
Title Bar
Axis Position
Parameters
N
avigation Bar
Information
Figure 2-1 The initial page
Title Bar
This area is displayed on every page, and from left to right are Page Name, System Status, and
Operation Mode in turn.
Page Name: displayed the current pages name, e.g. SIngleStep, Multi, Program.
System Status: displayed the current system status. There are six system statuses, as shown in
Table 2-1.
Table 2-1 The description of the system status
System Status Description
Not Ready
When power up the device, the system detects the signal Pump is turned OFF, this
system status is displayed.
Idle
When this system status is displayed, the signal Pump is turned ON, and the
signal RDY is also turned ON.
Only under this system status, the machine can run the programming after you has
completed the program and press down the START key.