ProNet Series AC Servo User's Manual
- 145 -
drives directly when multiple ProNet series servo drives are connected.
Example:
When a RS-485 network is composed of a PLC and three servo drives (A, B, and C), the cable wiring is shown as follows:
PLC→CN3 of A, CN4 of A→CN3 of B, CN4 of B→CN3 of C, CN4 of C→120Ω terminating resistance.
6.2 MODBUS Communication Related Parameters
Parameter No. Description
Setting
Validation
Control Mode Meaning
Pn700 Hex After restart ALL
Pn700.0 MODBUS baud rate
[0] 4800bps
[1] 9600bps
[2] 19200bps
Pn700.1 Communication protocol
selection
[0] 7,N,2(MODBUS,ASCII)
[1] 7,E,1(MODBUS,ASCII)
[2] 7,O,1(MODBUS,ASCII)
[3] 8,N,2(MODBUS,ASCII)
[4] 8,E,1(MODBUS,ASCII)
[5] 8,O,1(MODBUS,ASCII)
[6] 8,N,2(MODBUS,RTU)
[7] 8,E,1(MODBUS,RTU)
[8] 8,O,1(MODBUS,RTU)
Pn700.2 Communication protocol
selection
[0] SCI communication with no
protocol
[1] MODBUS SCI communication
Pn700.3 Reserved
Pn701 Axis address After restart ALL
Axis address of MODBUS protocol
communication