ProNet Series AC Servo User's Manual
- 91 -
Pulse Dividing Ratio Setting
Pn200
PG Dividing Ratio
Setting Range Setting Unit Factory Setting Setting Validation
16~16384 1Puls 16384 After restart
Set the number of pulses for PG output signals (PAO,/PAO,PBO,/PBO) externally from the servo drive.
Feedback pulses from the encoder per revolution are divided inside the servo drive by the number set in Pn200 before
being output. (Set according to the system specifications of the machine or host controller.)
The setting range varies with the number of encoder pulses for the servomotor used.
■Output Example
Pn200=16(when 16 pulses are output per revolution)
4.5.9 Speed coincidence output
The speed coincidence (/V-CMP) output signal is output when the actual servomotor speed during speed control is the
same as the speed reference input. The host controller uses the signal as an interlock.
Type Signal Name Connector Pin Number Setting Meaning
Output /V-CMP(/COIN)
CN1-11,12
(factory setting)
ON(low level) Speed coincides.
OFF(high level) Speed does not coincide.
Pn501
Coincidence Difference
Setting Range Setting Unit Factory Setting Setting Validation
0~100
rpm 10 Immediately
The /V-CMP signal is output when the difference between the speed reference and actual servomotor speed is less than
Pn501.
■Example
The /V-CMP signal turns ON at 1900 to 2100rpm
if the Pn501 parameter is set to 100 and the reference speed is
2000rpm.
■Note
This pin outputs the /COIN signal in position control mode, and the /V-CMP signal in speed control mode.
Speed
Position
Torque
Speed