ProNet Series AC Servo User's Manual
- 27 -
Terminal
Symbol
Name
Main
Circuit
Voltage(V)
Servo
Drive
Model
ProNet-
Servo
Drive
Model
Pronet-E-
Functions
resistor
connection
terminal
100
04B-08B 04B-08B
If using an internal regenerative resistor, please short
B2 and B3. Remove the wire between B2 and B3 and
connect an external regenerative resistor(provided
by customer) between B1 and B2, if the capacity of
the internal regenerative resistor is insufficient.
200 08A-50A 08A-50A
400
10D-75D 10D-50D
B1,B2 1AD-2BD
-
Connect an external regenerative resistor between
B1 and B2.
○
+ 1,
○
+ 2
DC reactor for
harmonic
suppression
terminal
200 02A-50A 02A-50A
Normally short ○+ 1and ○+2.
If a countermeasure against power supply harmonic
waves is needed, connect a DC reactor between ○+
1and ○+2.
400 10D-75D 10D-50D
○
-
Main circuit
minus terminal
200 02A-50A 02A-50A Normally not connected.
400 10D-75D 10D-50D
3.1.2 Typical Main Circuit Wiring Examples
Single-phase 200V ProNet-02A~04A/ Single-phase 200V ProNet-E-02A~04A
L1 L2
Single-phase 200~230V (50/60Hz)
+10%
-15%
Power OFF Power ON
1KM 1SUP
1KM
1Ry
L1
L2
W
V
U
M
PG
A(1)
B(2)
C(3)
D(4)
L2C
L
1C
CN2
1Ry
1D
+24V
0V
1Ry
1PL (Servo Alarm Display)
ALM+7
ALM-
8
ProNet
Series Servodrive
1
2
Ground Terminal
Encoder
Servodrive
Magnetic Contactor
Molded-case Circuit Breaker
Surge Protector
Noise Filter
Be sure to connect a surge suppressor to the
excitation coil of the magnetic contactor and relay.
B1
B2
B3
B1
B2
B3
External regenerator resistor
Note
1.The L1,L2,L3 and L1C,L2C terminals wiring method of ProNet-02A~04A/ProNet-E-02A~04A servo drives is different
from other ProNet series servo drives. Please note the specific terminal definition while wiring.
2.The main circuit power supply of ProNet-02A~04A/ProNet-E-02A~04A is Single-phase 200V