ProNet Series AC Servo User's Manual
- 48 -
3.5.9 Speed Control Mode
+
A/D
+24V
P
P
-
ref
40K
10K
40K
10K
1Ry
1D
+24V
0V
PAO+20
PAO-21
PBO+22
PBO-23
PCO+24
PCO-25
DGND50
TGON+
5
TGON-6
S-RDY+9
S-RDY-
10
V-CMP+11
V-CMP-12
ALM+7
ALM-
8
VREF+ 1
VREF-
2
DICOM
13
S-ON 14
P-CON
15
P-OT
16
N-OT 17
ALM-RST
39
CLR 40
P-CL 41
N-CL 42
Shield
ALM: Servo Alarm Output
Photocoupler Output:
Maximum Operating Voltage:DC30V
Maximum Output Current:DC50mA
Represents Twisted-pair Wires
Shell
Connect Shield to Connector Shell.
Signal allocatons can be modified:
S-ON: Servo ON
P-CON: P Control
P-OT: Forward Run Prohibited
N-OT: Reverse Run Prohibited
ALM-RST: Alarm Reset
CLR: Clear Error Pulse
P-CL: Forward Torque Limit
N-CL: Reverse Torque Limit
SHOM: Home
ORG: Zero Position
Signal Allocations can be Modified:
V-CMP: Speed Coincidence
COIN: Positioning Completion
TGON:Rotation Detection
S-RDY:Servo Ready
CLT:Torque Limit Detection
BK:Brake Interlock
PGC: Encoder C-Pulse Output
OT:Over Travel
RD: Servo Enabled Motor Excitation Output
HOME: Home Completion Output
PG Divided Ratio Output:
Applicable Line Receiver
AM26LS32A Manufactured by TI or the Equivalent.
ProNet
Series Servodrives
Speed Reference(±0~10V/Rated Speed)
3.3KΩ