ProNet Series AC Servo User's Manual
- 63 -
Pn305
JOG Speed
Setting Range Setting Unit Factory Setting Setting Validation
0~6000 rpm 500 Immediately
Set the utility function Fn002 (JOG Mode Operation) to the reference value of servomotor speed.
The servomotor can be operated using only the panel operator without reference from the host controller.
Please note that the Forward Run Prohibited (P-OT) and Reverse Run Prohibited (N-OT) signals are invalid during JOG
mode operation.
4.1.2 Trial Operation for Servomotor without Load from Host Reference
Check that the servomotor move reference or I/O signals are correctly set from the host controller to the servo drive.
Also check the wiring and polarity between the host controller and servo drive, and the servo drive operation settings are
correct. This is the final check before connecting the servomotor to the machine.
(1)Servo ON Command from the Host
The following circuits are required: External input signal circuit or equivalent.
0V
+24V
/S-ON
P-OT
N-OT
V-REF
13
30
17
16
14
CN1
13
1
17
16
14
CN1
32
+24V
/S-ON
P-OT
N-OT
PULS
SIGN
Speed Control
(Standard Setting)
[Pn005=H.□□0□]
Position Control
[Pn005=H.□□1□]
0V
S
p
eed Position
Tor
q
ue