Parameter
No.
Description
Setting
Validation
Control
Mode
Function and Meaning
[1] Homing in the reverse direction
Pn689.1 Search C-Pulse Mode
[0] Return to search C-Pulse when homing
[1] Directly search C-Pulse when homing
Pn689.2 Homing trigger starting mode
[0] Homing function disabled
[1] Homing triggered by SHOM signal (rising edge)
Pn689.3 Reserved
Pn690
Number of error
pulses during homing
Immediately P
unit10000P
Pn691
Number of error
pulses during homing
Immediately P
unit1P
Pn700
Hex After restart ALL
Pn700.0 MODBUS communication baud rate
[0] 4800bps
[1] 9600bps
[2] 19200bps
Pn700.1 MODBUS protocol selection
[0] 7N2MODBUS,ASCII
[1] 7E1MODBUS,ASCII
[2] 7O1MODBUS,ASCII
[3] 8N2MODBUS,ASCII
[4] 8E1MODBUS,ASCII
[5] 8O1MODBUS,ASCII
[6] 8N2MODBUS,RTU
[7] 8E1MODBUS,RTU
[8] 8O1MODBUS,RTU
Pn700.2 Communication protocol selection
[0]
No protocol SCI communication
[1] MODBUS SCI communication
Pn700.3 Reserved
Pn701
MODBUS Axis
address
After restart ALL
Axis address of MODBUS protocol communication
Pn702
Reserved
Pn703
CAN communication
speed
After restart ALL
Pn703.0 CAN communication baud rate
[0] 50Kbps
[1] 100Kbps
[2] 125Kbps
[3] 250Kbps
[4] 500Kbps
[5] 1Mbps
Pn704
CAN communication
contact
After restart ALL
CANopen Aix address of communication
Pn840
Hex After restart ALL
Pn840.0 Encoder model selection
[0]-[2] ReservedFor factory using
[3] 17-bit absolute encoder
[4] 17-bit incremental encoder
[5] Resolver

Table of Contents