3 - 8 Page Date: 20. April 2002
Section 3
Emergency Procedures
Pilot“s Operating Handbook
EXTRA 300L
3.8 EMERGENCY EXIT AFTER TURN OVER
1. Master switch OFF
2. Fuel shutoff valve OFF (Pull & Turn)
3. Seat belts OPEN
4. Parachute harnesses (if wearing a parachute) OPEN
5. Canopy handle PULL TO OPEN
N O T E
If canopy fails to open break the canopy.
6. Aircraft EVACUATE ASAP
3.9 ELEVATOR CONTROL FAILURE
In case of elevator control failure the aircraft can be flown with the elevator trim. In this case
trim nose up to the desired speed and control horizontal flight or descend with engine
power. For landing trim nose up and establish a shallow descend by adjusting throttle. To
flair the plane gently increase power to bring the nose up to landing attitude.