To replace an ExtremeSwitching 2000 W AC power supply, follow these steps:
1. Disconnect the AC power cord from the wall outlet and from the power supply.
2. Note the orientation of the installed power supply, and the location of the latching
tab at the right of the unit.
3. Push the latching tab toward the power supply handle and pull outward on the
handle to disengage the power supply internal connectors.
Figure 34: Removing an ExtremeSwitching 2000 W AC Power Supply
4. Carefully slide the power supply the rest of the way out of the switch.
Caution
Power supplies can become very hot during operation. Wear thermal
protective gloves when you remove a power supply from an operating
switch.
Note
If you are not installing a replacement power supply, install a cover over the
unoccupied power supply bay. Unoccupied bays must always be covered to
maintain proper system ventilation and EMI levels.
5. Verify that the replacement power supply is oriented the same way as the unit you
removed, and has the same airow direction.
Removing and Replacing Components Replace a 2000 W AC Power Supply
VSP 4900 Series Switches: Hardware Installation Guide 67