EasyManua.ls Logo

Extron electronics DXP 44 HD 4K PLUS - Page 81

Extron electronics DXP 44 HD 4K PLUS
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DXP HD 4K PLUS Series • SIS Configuration and Control 73
Command ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
IP Control Port Commands (continued)
IP Setup
Set gateway IP address
24
EX3@CG} IpgX3@]
Set the gateway IP
address.
View gateway IP address
ECG} X3@]
View the gateway IP
address.
View MAC address
ECH} X3#]
IphX3#]
00-05-A6-xx-xx-xx
Verbose modes 2 and 3
View number of open
connections
ECC} X3$]
IccX3$]
View the number of open
connections.
Verbose modes 2 and 3
Set DNS server address
EX3)DI} IpdX3)]
Set the IP address of the
DNS server.
View DNS server address
EDI} X3)]
View the DNS server
address.
Verbose modes 2 and 3
KEY:
X# = Enable or disable
0 = Disable DHCP mode (default), 1 = Enable DHCP mode
X3) = IP address
nnn.nnn.nnn.nnn (192.168.254.254 = default)
X3@ = Gateway address
nnn.nnn.nnn.nnn (0.0.0.0 = default)
X3# = MAC address
00-05-A6-xx-xx-xx
X3$ = Open connections
0-<maximum number of open connections>
Date and Time
Set date and time
EX3&CT} Ipt X3&]
Set the date and time.
View date and time
ECT} X3*]
View the date and time.
KEY:
X3& = Date and time
In the format MM/DD/YYHH:mm:SS
MM = month: 01 (January) to 12 (December)
DD = day: 01 to 31 (depending on the month)
YY = year: 00 to 99 (last two digits)
HH = hour: 00 to 23, mm = minute: 00 to 59, SS = second: 00 to 59
X3* = Date and time (view only)
In the format DAY,
DD
MMM
YYYY
HH:mm:SS
DAY =day of the week: Mon to Sun
DD = date: 01 to 31 (depending on the month)
MMM = month: 01 to 12
YYYY = year: 2000 to 2099
HH = hour: 00 to 23, mm = minute: 00 to 59, SS = second: 00 to 59

Table of Contents

Other manuals for Extron electronics DXP 44 HD 4K PLUS

Related product manuals