SSP 200 • Panel Features 12
• 2-Channel (2-CH):
• Any source coming through analog input 5.
• If a 2‑Channel PCM digital signal is present on any of the digital inputs, both the
PCM and the 2‑CH LEDs light.
• If a Dolby Digital 2/0 or Dolby Digital 2/0 Surround source is present, both the
and the 2‑CH LEDs light.
• If a DTS 2‑Channel source format is present, both the DTS and 2‑CH LEDs
light.
• ATMOS: Dolby Atmos source material
• DTS:X: DTS:X source material (HDMI only)
• HDCP: HDMI source material (HDMI only)
• EXP: Valid EXP connection. Blinks when the assigned EXP input is selected.
Input Selection
DTS
D
PCM
2-CH
DTS: X
ATMOS
HDCP
EXP
SOURCE
INPUT
1 2 3 4 5
VOLUME
OUTS
1(LF) 2(RF) 3(C) 4(SUB) 5(LS) 6(RS) 78 910(MIX)
RS-232
Tx Rx G
1 THRU
INPUTS
2
5
LR
34
Figure 11. SSP200 Input Selection Switches
D
Input selection buttons — Push one of the buttons to select between the five audio
inputs. When a button is selected, the button lights green indicating it is the active input.
For digital inputs 1 through 4, the button turns amber when it is selected and the digital
clock signal has not been detected.
The Input 5 button turns red when the analog input is clipping. The Analog Input Gain
Level can be adjusted with the volume adjustment knob (see page 13).
The SSP accepts four digital inputs and one analog input (see Rear Panel Features
on page6):
• Input 1 accepts digital signals through an HDMI cable.
• Input 2 accepts digital signals through a S/PDIF coaxial cable.
• Inputs 3 and 4 accepts digital signals through S/PDIF optical cables. The SSP 200
supports TOSLINK or TOSLINK‑compatible optical connectors that conform to
IEC‑958, S/PDIF standards.
All four digital inputs accept 16‑ to 24‑bit PCM audio at 32kHz, 44.1kHz, 48kHz,
88.2kHz, 96kHz, and 192kHz sample rates. They support Dolby Digital and DTS
source formats.
• Input 5 accepts a balanced or unbalanced analog input through a 6‑pin captive
screw connector. The unit can be configured to accept:
• A stereo signal
• A mono signal (see Listening Mode Options on page27)
The input can also be selected using PCS (see Product Configuration Software on
page29) and SIS commands (see SIS Configuration and Control on page62).
11