SSP200 • Product Configuration Software 59
4. Scroll down the page until you locate the firmware for the SSP 200.
5. Click Download. The product download screen opens.
6. Enter the required user login information. An executable (.exe) file downloads to the PC.
Run this program to place the firmware on the PC. Make a note of the folder where the
firmware file was saved.
ATTENTION:
• The extension of the firmware file must be .eff. Opening a file with an incorrect
extension may cause the device to stop functioning.
• L’extension du fichier firmware doit être .eff. Si un fichier est ouvert avec une
mauvaise extension, l’appareil peut arrêter de fonctionner.
Loading the Firmware to the SSP200
To load a new version of firmware to the SSP200 using PCS:
1. Connect your computer to the SSP200 via either the device rear RS‑232 or LAN port
(see Rear Panel Features starting on page6) or the front panel USB Config port
(see Front Panel Features starting on page11).
2. If needed, download and install PCS to your computer (see Downloading PCS from
the Extron Website on page29).
3. If needed, download the latest version of SSP200 firmware to your computer (see
Downloading the SSP 200 Firmware on page58).
4. Open PCS by clicking the desktop icon, if available or using your desktop Start menu
to make the following selections: Start > All Programs > Extron Electronics >
Extron Product Configuration Software.
The Product Configuration Software window opens to the Device Discovery
screen (see figure55).
SSP 200 192.168.254.254 SSP 200
1
1
2
2
Figure 55. PCS Device Discovery Screen
5. On the Device Discovery screen, select the SSP 200 (
1
).
6. Click Connect (
2
).
7. The Product Configuration Software opens to the main page (see figure56). Click
the device menu arrow next to the name of the device (
1
).
Figure 56. Accessing the Device PCS Menu
55
56