SSP 200 • Panel Features 15
Reset Modes Summary
Mode Activation Result
1
Hold in the recessed Reset button while
applying power to the device.
Restores the factory‑installed firmware.
Maintains all user settings (audio adjustments,
IP settings, and so on).
4
Hold in the Reset button until the Reset
LED blinks twice (once after approximately
3 seconds and again after 6 seconds).
Then, within 1 second press Reset
momentarily (for less than 1 second).
Sets the IP address, subnet address, and
gateway address to the factory defaults.
Sets port mapping to the factory default.
Turns DHCP off.
Turn event scripts off.
The Reset LED blinks four times in quick
succession during the reset.
5
Hold in the Reset button until the Reset
LED blinks three times (once after
approximately 3 seconds, again after
6 seconds, and then again after 9 seconds);
then within 1 second press Reset
momentarily (for less than 1 second).
Performs a complete reset to factory defaults. The
password reverts to extron.
The Reset LED blinks four times in quick
succession during the reset.
Full system resets can also be performed using SIS commands (see Resets on page78).
Front Panel Security Lockout (Executive Mode)
When the front panel is locked, the user cannot make any input changes from the front
panel. If the user attempts to make changes with the front panel locked out, all the input
button LEDs flash simultaneously. The lockout does not block changes made using SIS
commands or PCS. There are three lockout modes available:
Mode 1 — All front panel controls are locked. No adjustments can be made.
Mode 2 — All front panel controls are locked except for volume control. This allows the
volume to be adjusted, without the ability to change inputs.
Mode 3 — All front controls are locked, except for input selection buttons.
This feature can only be set using SIS commands (see SIS Configuration and Control on
page62) or PCS (see Front Panel Lockout (Executive Mode) on page52).