Command and Response Tables
Command SIS Command
(Host to Device)
Response
(Device to Host)
Additional Description
Firmware Version/Part Number/Information Queries
Query model name
1I
Verbose modes 2/3
SSP•200]
Inf01*SSP•200]
Query model description
2I
Verbose modes 2/3
Surround•sound•processor]
Inf02*Surround•sound•processor]
Query firmware version
Q
Verbose modes 2/3
{version x.xx}]
Ver01*{version x.xx}]
Query firmware version
(advanced)
X@
Q
Verbose modes 2/3
{Specic version info}]
Ver
X!
*{Specic version info}]
Query firmware version
(w/build)
*Q
Verbose modes 2/3
{version x.xx.xxxx}]
Bld{version x.xx.xxxx}]
Query Kernel/Library
version
**Q
Verbose modes 2/3
{version x.xx.xxxxLX}]
Lib{version x.xx.xxxxLX}]
Query system
messaging version
***Q
Verbose modes 2/3
{version}]
Idv{version x.xx}]
Query part number
N
Verbose modes 2/3
zz-zzzz-zz]
Pnozz-zzzz-zz]
KEY:
X!
= Firmware query 0 = Detailed version information (includes all 2Q, 3Q, and 4Q) 1 = Firmware version
2 = Final Stage bootloader version 3 = Factory Base Code version 4 = Updated Firmware version
Ethernet Data Port
Set current connector
port timeout
E0*X$TC} Pti0*X$]
View current connector
port timeout
E0TC} X$]
Set global IP port timeout
E1*X$TC} Pti1*X$]
View global IP port
timeout
E1TC} X$]
KEY:
X$
= IP Timeout: The number of seconds before timeout on IP connections (min=1, max =65000 and default = 30 (300
seconds). If no data is received during the timeout period, the Ethernet connection is closed. Each step = 10 seconds.
Serial Data Port (including Device control and Host control ports)
Configure parameters
E1*X1!X1@X1#X1$CP} Cpn1•CcpX1!X1@X1#X1$]
View parameters
E1CP} X1!X1@X1#X1$]
Configure mode
E1*X1%CY} Cpn1•CtyX1%]
View mode
E1CY} X1%]
Configure flow control
E1*X1^X1&CF} Cpn1•CX1^X1&]
View flow control
E1CF} X1^X1&]
KEY:
X1!
= Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 14400, 19200, 28800,
38400, 57600, 115200 (default=9600)
X1@
= Parity:
Odd, Even, None, Mark, Space
[only use the first letter] (default=N=None)
X1#
= Data bits: 7, 8 (default=8)
X1$
= Stop bits: 1, 2 (default=1)
X1%
= Port type: 0=RS232 1=RS422 2=RS485 (default=0=RS232)
X1^
= Flow Control: Hardware, Software, None [only use the first letter] (default=N=None)
X1&
= Data Pacing [specified in milliseconds between bytes]: 00001000 (default=0 ms).
For host port(s), this value is ignored – always returns 0.