SSP 200 • SIS Configuration and Control 70
Command SIS Command
(Host to Device)
Response
(Device to Host)
Additional Description
IP Setup Commands
Set Unit name
EX2!CN} Ipn•X2!]
Set Unit name to factory
default
E•CN} Ipn•X3)]
View Unit name
ECN} X2!]
Set date/time
EX2@CT} Ipt•X2@]
View date/time
ECT} X2@]
Viiew date/time in Hex
E*CT} X2*]
View GMT offset
ECZ}
Verbose modes 2/3
X1(]
IpzX1(]
Set DHCP on
E1DH} Idh1]
Set DHCP off
E0DH} Idh0]
View DHCP mode
EDH} X2)]
Set IP address
EX2#CI} Ipi•X2#]
View IP address
ECI} X2#]
View hardware address
(MAC)
ECH}
Verbose modes 2/3
X2$]
Iph•X2$]
Set subnet mask
EX2%CS} Ips•X2%]
View subnet mask
ECS} X2%]
Set gateway IP address
EX2#CG} Ipg•X2#]
View gateway IP address
ECG} X2#]
Set IP
E1*X2#CISG} Cisg•1*X2#/X2&*X2#]
Set IP/Subnet
E1*X2#*X2%CISG} Cisg•1*X2#/X2&*X2#]
Set IP/Subnet/Gateway
E1*X2#*X2%*X2#CISG} Cisg•1*X2#/X2&*X2#]
View IP/Subnet/Gateway
(all)
E1CISG}
Verbose modes 2/3
X2#/X2&*X2#]
Set DNS Server IP
address
EX2#DI} Ipd•X2#]
View DNS Server IP
address
EDI}
Verbose modes 2/3
X2#]
View connection listing
ECC}
Verbose modes 2/3
{Number of connections}]
Icc{Number of connections}]
View device info
EBC}
<part number>null<rmware ver>null<box name>null
<6-byte MAC address in binary>
KEY:
X1(
=
GMT offset value: This represent hours and minutes (hh:mm) offset from Greenwich Mean Time (GMT).
X2)
= DHCP status: 0 = Off (default) 1 = On
X2!
=
Unit name: A text string up to 63 characters drawn from the alphabet (A‑Z), digits (09), and minus sign/hyphen (‑).
X2@
=
Local date and time format: MM/DD/YY-HH:MM:SS
X2#
= IP Address: xxx.xxx.xxx.xxx . Leading zeros in each of the 4 fields are optional in setting values and are suppressed
in responses.
X2$
=
Hardware MAC address: 00-05-A6-xx-xx-xx
X2%
= Subnet mask: xxx.xxx.xxx.xxx. Leading zeros in each of the 4 fields are optional in setting values and are
suppressed in responses.
X2&
= Prefix (subnet mask bits): Subnet 255.255.0.0 is represented as a prefix value of /16.
X2*
=
Date/Time returned in 7 Hex bytes month, day, year, hour minutes, seconds, day of the week (1 begins on Sunday).
X3)
=
Default name: Combination of model‑name and last 3 pairs of MAC address (for example: SSP-200-01-23-4D).