6
J6
J12
J13
J5
J10
J11
J14
J7
+
-
F
SW1 SW2 SW3
J15
J1 J2 J3 J4
M2
M1A
M1
DL1 DL2
DL10
DL11
DL12
DL13
DL14
DL18
DL17
DL7
DL5
DL8
DL6
DL9
DL16
DL3
DL4
DL15
2Easy BUS
OPEN
CLOSE
FSW
STOP
ALARM
GND
+24
3 4 5
6
7
8 9 10 11 12 13 14 15 16 17 18 19 20 21
22 23 2
2
+24
+24
+24
+24
OUT1
OUT2
OUT3
Relay NO
Relay NC
GND
LAMP
LOOP 1
LOOP 2
MOTOR
POWER
SUPPLY
BATTERY
ENCODER
DISP1
M
SW4
1 2
2 24 5 6
7
Fig.1
E680 CONTROL BOARD
DISP1
Signalling/Programmingdisplay
DL1
BUSDevicestatus
DL2
BUSstatus(seeparagraph5.3)
DL3
LOOP1status
DL4
LOOP2status
DL5
Boardfailuresignal
DL6
Not used
DL7
Encoderstatus
DL8
Not used
DL9
Boardpowersupplypresent
DL10..DL14
InputsstatusLEDs(seeparagraph4.1)
DL15
Releasedbarsignal
DL16
Batterypowersignal
DL17
Radiochannel1activity
DL18
Radiochannel2activity
J1
Inputsignalconnector
J2
Digitaloutputconnector
J3
Signallinglampconnector
J4
Detection loop connector
J5
Motor connector
J6
BUS2Easyconnector
J7
Beam movement encoder connector
J10
Decoder / Minidec / RP-RP2 radio board connector
J11
Released bar detection connector
J12
Emergencybatteryconnector
J13
Continuouspowervoltageconnector
J14
USBconnectorforfirmwareupgrade
J15
Integratedflashing
trafficlightconnector
F
Programmingkey“F”
+
Programmingkey“+”
-
Programmingkey“-”
SW4
Programmingkey“SETUP”
M1/M1A/M2
Optionalmoduleconnector(Connectivity):
1. WARNINGS
Warning - Before carrying out any workon the control board
(connections,maintenance,etc.)always:
• cutofftheelectricalpower;
• install a differentialmagnetothermic switch witha suitable
activationthresholdupstreamfromthesystem;
• alwaysseparatethepowercablesfromthecontrolandsafety
cables(button,receiver,photocells,etc.);
• avoidanyelectricaldisturbance using separate sheaths or a
shieldedcable(withtheshieldconnectedtotheearth).
2. DESCRIPTION OF THE COMPONENTS
Mains
power
voltage
90-240 V~ +6% -10%
connected to
switchingpowersupply
Continuous
power voltage
36 V
"
Absorbed power 270W
Accessories
power supply
24 V
"
Max accessories
current
800 mA
Operating ambient
temperature
from-20°Cto+55°C
Protection fuses 4self-restoring
3. TECHNICAL SPECIFICATIONS
Pause time Programmable(from 0 seconds to 4.1
minutes)
Work time
Programmable(from0to4minutes)
Motor power Programmableon50levels
Motor speed Programmableon10levels
Programmability 3 configuration levels for greater flexibility
ofuse
Rapid connector 1 5-pin connectorforMinidecradio board,
Decoder,RP/RP2
Programmable
outputs
4 programmable outputs in 19 different
functions
Specifications
Deceleration management, encoder,
multi-functiondisplay,BUStechnology
andBUILT-INMETALMASS DETECTOR,
USBconnectorforfirmwareupgrade