13
Display
Function
Default
P1
Output 1 Polarity
Allowssettingoftheoutputpolarity:
Y outputNC
no outputNO
NOTE:iftheoutputsettingis00 (Failsafe),
keepthevaluesettono
no
o2
Output 2
Output2signaltype,see“Output 1”
03
P2
Output 2 Polarity
Output 2 polarity,see parameter regarding
“Output 1 Polarity”
no
o3
Output 3
Output3signaltype,see“Output 1”
19
P3
Output 3 Polarity
Output 3 polarity,see parameter regarding
“Output 1 Polarity”
no
o4
Output 4
Output4signaltype,see“Output 1”
01
P4
Output 4 Polarity
Output 4 polarity,see parameter regarding
“Output 1 Polarity”
no
o5
Integrated flashing lamp operating mode
Letsyouchoosebetweentwooperatingmodes
fortheintegrated flashing lamp (if present)
connectedtooutputJ15.
01 “Trafc light” mode (steady green
when paused/open, ashing red when
moving,steadyredwhenclosed)
02 ”Flashing lamp” mode (ashing red
when bar is moving, off in all other
cases)
01
AS
Service request (linked to the following
two functions):
If activated, at the end of the countdown
(whichcanbesetwiththetwofollowing“Cycle
Programming”functions)itactivatestheLAMP
outputfor4secevery30sec(servicerequest).
It can be useful for setting programmed
maintenance work.
Y Active
no Disabled
no
nc
Cycle programming in thousands:
Is used to set a countdown of the system
operation cycles; the value can be set from
0 to 99 (thousands of cycles). The value
displayed is updated with the succession of
the cycles, interacting with the value of nC
(99 decrements of nc correspond to 1
decrement of
nC).
Thefunctioncanbeused,togetherwithnC,
toverifytheuseofthesystemandforuseof
“ServiceRequest”.
00
Display
Function
Default
nC
Cycle programming in hundreds of
thousands:
Is used to set a countdown of the system
operationcycles;thevaluecanbesetfrom0
to99(hundredsof thousandsofcycles).The
valuedisplayedisupdatedwiththesuccession
of the cycles, interacting with the value of
nc.(1decrementofnC corresponds to 99
decrements of
nc).
Thefunctioncanbeused,togetherwithnc,
toverifytheuseofthesystemandforuseof
“ServiceRequest”.
01
St
AUTOMATED SYSTEM STATUS:
Thisallowsyoutochoosewhethertoquittheprogramme
and save the data.
Y=quitandsavethedata
no=quitwithoutsavingthedata
Onquittingtheprogramme,presstheFkeytodisplay
againthestatusoftheautomatedsystem.
You can go to St at any time by simultaneously
pressing F and -
6.1 Conguring the loop detector
TheE680boardfeaturesanintegratedmetalmassdetectorforthe
inductiondetectionofvehicles.
6.1.1 Specications:
• Galvanic separation between the detector electronics and the
loop electronics
•
Automaticalignmentofthesystemimmediately following
activation
•
Continuousresettingofthefrequencydrifts
• Sensitivityindependentofloopinductivity
• Adjustmentoftheloopworkfrequencywithautomaticselection
• OccupiedloopmessagewithLEDdisplay
• LoopstatusaddressableonoutputsOUT1,OUT2,OUT3and
OUT 4
6.1.2 Connection:
Connectthedetectionloops according to the layout on page 7,
Fig.2
-Terminals24-25forLOOP1=loopwithgateopeningfunction;
-Terminals26-27forLOOP2=loopwithclosingand/orsafety
whenclosingfunction.
Formoreinformationontheeffectoftheloopsignalsontheautomated
system, refer to the logics tables in paragraph 10 “OPERATING
LOGICSTABLE”.
To enable the functionality of the connected loops, enter Basic
congurationmodeandsetparametersL1 and L2 on Yconsistently
withthe number and type of connected loops.If only one loop is
installed,enableonlythecorrespondingprogrammingstep.
TheloopdetectoroperatingstatusisindicatedbytheDL3andDL4
statusLEDs.