15
04
Activation of DEAD-MAN opening (command always pressed). Releasing the OPEN
command will stop operation
Y
= active
no = disabled
05
Whenthisfunctionisactivated,theOPEN commandduringopeningwillstopmovement.
If parameter 06 is nothesystemisreadyforopening.
If parameter 06 is Ythesystemisreadyforclosing.
Y=whenopeningitstops
no = disabled
06
Whenthisfunctionisactivated,theOPEN commandduringopeningreversesmovement.
If parameters 05 and 06 are noOPENwillhavenoeffectduringopening.
Y=whenopeningitreverses
no = disabled
07
Whenthisfunctionisactivated,theOPEN commandduringpausestopsoperation.
If parameters 07 and 08 are noOPENresetsthepausetime
Y=wheninpauseitstops
no = disabled
08
Whenthisfunctionisactivated,theOPEN commandduringpausecausesclosing.
If parameters 07 and 08 are noOPENresetsthepausetime.
Y
=wheninpauseitcloses
no = disabled
09
When this function is activated, the OPEN command during closing stops operation,
otherwise it reverses movement.
Y = stops
no = reverses
10
Activation of DEAD-MAN closing (command always pressed). Releasing the CLOSE
command will stop operation
Y
= active
no = disabled
11
Whenthisfunctionisactivated,theCLOSE commandhaspriorityoverOPEN,otherwise
OPENhaspriorityoverCLOSE.
Y = active
no = disabled
12
Whenthisfunctionisactivated,theCLOSE commandcommandsclosingwhenreleased.
AslongasCLOSEisactivated,theunitstaysinclosingpre-ashing.
Y = closes when released
no=closesimmediately
13
Whenthis functionis activated,the CLOSE commandduring openingstops operation,
otherwisetheCLOSEcommandcommandsreverseimmediatelyorwhenopeningiscom-
pleted(seealsoparameter14)
Y
=
CLOSE stops
no = CLOSE reverses
14
When this function is activated, and if parameter 13 is no, the CLOSE command
commandsimmediateclosingattheendoftheopeningcycle(storesCLOSE).Ifparameters
13 and 14 are noCLOSEcommandsimmediateclosing.
Y = closes at the end of
opening
no=immediateclosing
15
When this function is activated, with the system blocked by a STOP, a next OPEN
moves in the opposite direction. If parameter
15 is noitalwayscloses.
Y = moves in the opposite
direction
no=alwayscloses
16
Whenthis function isactivated, during closing,the CLOSING SAFETIES stop and allow
motiontoresumewhentheyaredisengaged,otherwisetheyimmediatelyreverseopening.
Y=closeswhendisengaged
no = immediate reverse
17
Whenthisfunctionisactivated,theCLOSING SAFETIEScommandclosingwhentheyare
disengaged(seealsoparameter18).
Y =
closing when FSW
isdisengaged
no = disabled
18
When this function is activated, and if parameter 17 is Y, the unit will wait for the
opening cycle to end before executing the closing command provided by the
CLOSING SAFETIES.
Y = closes at the end of
opening
no = disabled
19
Whenthisfunctionisactivated,duringclosing,LOOP2stopsandallowsmotiontoresume
whenitisdisengaged,otherwiseitimmediatelyreversesopening.
Y=closeswhendisengaged
no = immediate reverse
20
Whenthisfunctionisactivated,LOOP2commandsclosingwhenitisdisengaged(seealso
parameter 21).
Y = closes if LOOP2 is clear
no = disabled
21
Whenthisfunctionisactivated,andifparameter21 is Y,theunitwillwaitfortheopening
cycletoendbeforeexecutingtheclosingcommandprovidedbyLOOP2.
Y = closes at the end of
opening
no = disabled
22
When this function is activated: incase of a blackout, once electricalpower has been
restored,ifanOPENcommandisnotactivetheautomatedsystemreclosesimmediately.
Y = active
no = disabled
23
LOOP 1commandsopeningand,oncecompleted,itclosesifdisengaged(usefulincase
ofvehiclebacking-upwithconsecutiveloops).Ifdisabled,whenLOOP1isdisengaged,it
does not close.
Y = closes if LOOP1 clear
no = disabled
24
When this function is activated, an open or close command is only carried out after
the safeties have been disengaged.
Y = active
no = disabled
25
A.D.M.A.P. function
Whenthisfunctionisactivated,theresultisoperationofsafeties compliant with French
regulations.
Y = active