16
ENGLISH
26
Whenthisfunctionisactivated,theCLOSING SAFETIESduringclosingstopandreverse
movementwhentheyaredisengaged,otherwisetheyreverseimmediately.
Y = stops and reverses when
disengaged.
no=reversesimmediately.
27
DO NOT CHANGE
no
28
DO NOT CHANGE
no
29
DO NOT CHANGE
no
30
When this function is activated, the LOOP1 commands are prioritised rather than the
LOOP2 commands.
Y = active
no = disabled
A0
HOLD CLOSE / HOLD OPEN function
Whenthisfunctionisactivated,theautomatedsystemwillmonitorthepositionofthebeam
at setintervals(seeparameter
A1
).Ifthebeamisnotcompletelyclosedorcompletely
open (dependingonthelogicalconditionoftheboard),theautomatedsystemwillcommand
aCLOSEorOPENmovementtobringthebeambacktothecorrectposition,foramaximum
of3seconds.If,whenthe3secondshaveelapsed,thebardoesnotgobacktocompletely
closed/openposition(e.g.becausethebarisblocked),thefunctionwillbedisableduntilthe
nextOPENcommandisreceived.
Y
A1
HOLD CLOSE / HOLD OPEN function activation time
This parameter indicates the time interval between two activations of the HOLD OPEN /
HOLDCLOSEfunction,expressedinminutes.(from00 to 99)
60
r1
Loop 1 frequency reading
Thismenuitemletsyouverifythereadingofthecurrentoscillationfrequencyoftheloop
connectedtotheLoop1input.Theindicationshouldbereadasfollows:
Firstdigit:tens(kHz)
Seconddigit:units(kHz)
Decimalpoint:hundreds(kHz)
Forexample,thereading05. referstoareadingof105kHz
Read-only parameter
r2
Loop 2 frequency reading
Thismenuitemletsyouverifythereadingofthecurrentoscillationfrequencyoftheloop
connectedtotheLoop2input.(seeparameter r1forexplanationsonhowtoreadthe
indicatedvalue)
Read-only parameter
F1
Loop 1 frequency selection
Thisparameterletsyousetanoscillationfrequencyspecifictotheloopconnectedtothe
Loop1input,orletsthesystemchoosethemostadequatesettingamongthe4available.
A Automaticselection
1-2-3-4 Frequency1-2-3-4
Note: When you exit theAdvanced configuration menu after having changed the loop
operationfrequencysetting,thesystemwillberecalibrated.Thiswillprovideanupdated
frequencyreadingonceyoure-enterthemenutoconsultthevaluesofparametersr1 or
r2
A
F2
Loop 2 frequency selection
Thisparameterletsyousetanoscillationfrequencyspecifictotheloopconnectedtothe
Loop2input,orletsthesystemchoosethemostadequatesettingamongthe4available.
A Automaticselection
1-2-3-4 Frequency1-2-3-4
Note: When you exit theAdvanced configuration menu after having changed the loop
operationfrequencysetting,thesystemwillberecalibrated.Thiswillprovideanupdated
frequencyreadingonceyoure-enterthemenutoconsultthevaluesofparametersr1 or
r2
A