17
ENGLISH
h1
LOOP 1 holding time
Isusedtosetpresencetimeonloop1.Whenthistimehaselapsed,theboardwillself-
calibrateandsignal“loopclear”(LEDDL3off).Whentheboardisturnedon,anautomatic
resetiscarriedout.
Y 5minutes
no innite
no
h2
LOOP 2 holding time
Isusedtosetpresencetimeonloop2.Whenthistimehaselapsed,theboardwillself-
calibrateandsignal“loopclear”(LEDDL4off).Whentheboardisturnedon,anautomatic
resetiscarriedout.
Y 5minutes
no innite
no
H1
Loop 1 articulated lorry function
Thisfunctionletsyouincreasethelevelofsensitivityatthetimeofdetection,toallowcorrect
detectionevenincaseofverytallvehiclesorduringthetransitofatractorandtrailer.
Y enabled
no disabled
Y
H2
Loop 2 articulated lorry function
Thisfunctionletsyouincreasethelevelofsensitivityatthetimeofdetection,toallowcorrect
detectionevenincaseofverytallvehiclesorduringthetransitofatractorandtrailer.
Y enabled
no disabled
Y
t
Work time (time-out)
Maximumworktimeoftheautomatedsystembeforethemotorstops,iftheopenorclose
positionisnotreached.ThevaluecanbesetfromO to 59sec.inonesecondsteps.Next,
thedisplaychangestominutesandtenthsofasecond(separatedbyadecimalpoint)and
timeisadjustedin10-secondstepsuptothemaximumvalueof4.1minutes.
30
St
STATUS OF THE AUTOMATED SYSTEM:
Exitfromprogramming,storageofdataandautomatedsystemstatusdisplay.
6.3 Pre-Dened Parameter Sets
Thetablebelowshows,foreachsetofpre-definedparameters,the
valuesthattheywillloadintheboardmemory.
Basic Configuration
dF
01 02 03 04 05 06
At
01 02 03 04 05 06
bu
LO
E E E E E E
PA
20 20 20 20 20 20
So
10 10 10 10 10 10
Sc
10 05 05 04 02 02
L1
no no no no no no
L2
no no no no no no
S1
05 05 05 05 05 05
S2
05 05 05 05 05 05
Advanced Configuration
Thefollowingtableshows,foreachsetofpre-definedparameters,
thevalues thattheywillloadintheboardmemory,in advanced
configuration.
dF
01 02 03 04 05 06
FO
25 25 30 28 30 40
FC
25 25 30 28 30 40
PF
no no no no no no
tP
00 00 00 00 00 00
oc
35 35 38 32 32 32
FS
no no no no no no
o1
00 00 00 00 00 00
P1
no no no no no no
o2
03 03 03 03 03 03
P2
no no no no no no
o3
01 01 01 01 01 01
P3
no no no no no no
o4
02 02 02 02 02 02
P4
no no no no no no
o5
01 01 01 01 01 01
AS
no no no no no no
nc
00 00 00 00 00 00
nC
00 00 00 00 00 00