6.4 “Expert” default parameters
Thefollowingtablecontainsthepre-definedsettingsthatcharacterize
thevariousoperationlogics.
Step. A A1 E P PA Cn Ca C
01
Y Y N N Y N Y N
02
N N N Y Y Y Y Y
03
N N N N N N N N
04
N N N N N N N Y
05
N N Y N N N N N
06
N N Y N N N N N
07
N N N N N N N N
08
N N N N N N N N
09
N N N N N N N N
10
N N N N N N N Y
11
N N N N N N N N
12
N N N Y Y N N N
13
N N N N N N N N
14
N N N Y Y Y Y N
15
N N N N N N N N
16
N N N Y Y N N N
17
N Y N N N N N N
18
N Y N N N N N N
19
N N N Y Y N N N
20
N Y N Y Y Y Y N
21
N Y N Y Y Y Y N
22
N N N N N N N N
23
N N N Y Y N N N
24
N N N N N N N N
25
N N N N N N N N
26
N N N N N N N N
27
N N N N N N N N
28
N N N N N N N N
29
N N N N N N N N
30
N N N N N Y Y N
7. START-UP
7.1 Verifying the diagnostic LEDs
Beforestartinguptheboard,itisnecessarytoverifythatthestatus
ofthediagnosticLEDscorrespondstothelogic.Saidstatusmust
coincidewiththeindicationsinFig.4,situationwhichreflectsthatof
an automated system that is CLOSED and ready to open.
The FSW, STOP and ALARM LEDs are safety inputs with
NC contacts, therefore the related LEDs must be ON
when the automated system is at rest, and go off when
the device connected is engaged.
The OPEN and CLOSE inputs are NO contact inputs,
therefore the related LEDs must be OFF when the
automated system is at rest, and go on when the device
connected is active.
The BUS status must correspond to DL2 (green) on xed
and DL1 (red) off. The BUS menu of the
Basic conguration must display the
indication shown to the side conrming
the fact that there are no engaged
photocells or active pulse generators.
7.2 Setup
Beforebeing put into operation, theE680board requires a setup
procedureduringwhichtheautomatedsystemdeterminestherotation
angleofthebeamandconsequentlyitstravel.Thesemeasurements
allowcorrectmanagementofmotordecelerationsandacceleration
ramps.
At rst start-up the board will signal the need for a setup
cycle, by displaying a ashing S0.
Forsetup,proceedasfollows:
• Usingtheparameter“Mt”inBasicconfigurationmode,checkthat
theopening/closingmovementcorrespondstothepressedkey
(+/-);ifnot,gotothemotorwiringandreversethetwoconductors
L1andL3,asshowninFig.14,Ref.d
•
Place the automated system in closing position using the
parameter“Mt”inBasicconfigurationmodeorusingtherelease
device,asshowninparagraphs6and7onpage4.
• PressandholdSW4 (“SETUP” programming key) until the
automatedsystembeginsaslowopeningmovement.Onthe
displayS1willflashindicatingthestartoftheprocedure.
• Oncethemaximumopeningpositionisreached,theautomated
systemwillstopautomatically.
• Next, the automated system will start the beam closing
movement.ThedisplaywillflashtheindicationS3.
•
Oncetheclosingpositionhas been reached, the automated
systemwillstopautomaticallyandthedisplaywillgobackto
showingtheindicationofthecurrentstatusoftheautomated
system(00 - closed).
8. TESTING THE AUTOMATED SYSTEM
Onceprogrammingiscompleted,ensurethatthesystemisoperating
correctly.
Verifyespeciallythecorrectregulationoftheautomatedsystempower
andcorrectoperationofthesafetydevicesitisconnectedtoandverify
thattheautomatedsystemconformstocurrentsafetystandards.