24
Bar length
Installed
accessories
2 m 2,5 m 3 m 3,5 m 4m
4 m
(with
coupling
)
4,5 m 5 m
5 m
(with
coupling
)
No
accessories
1 1 2 2 2 3 3 3 3
Lights
1 1 2 2 2 3 3 3
Lights / Skirt
1 1 2 3 3 3 3
Lights / Foot /
Skirt
1 2 2 3 3 3 3
Lights / Foot
1 2 2 3 3 3 3
Foot
1 1 2 3 3 3 3
Skirt
1 1 2 2 3 3 3
Skirt/Foot
1 2 2 3 3 3 3
Table 4
Bar length
Installed accessories
5 m
(without
coupling)
5 m 5,5 m 6 m 6,5 m 7 m 7,5 m 8 m
No accessories
4 4 5 5 5 5 5 6
Lights
4 4 5 5 5 5 6 6
Lights / Skirt
4 5 5 6 6 6 6
Lights / Foot / Skirt
5 5 5 5 6 6
Lights / Foot
4 5 5 5 5 6 6 6
Foot
4 5 5 5 5 5 6 6
Skirt
4 5 5 5 5 6 6
Skirt/Foot
5 5 5 5 5 6
Table 5
13. DEFAULT SELECTION TABLES (dF parameter)
Thepurposeofthetwofollowingtablesistodetermine,dependingonthelengthofthebarandthenumberandtypeofaccessoriesinstalled,
thecorrectdefaultvaluetosetinthefirstBasicprogrammingfunction.
Table4referstothebalancespringforbarlengthsequaltoorshorterthan5mandfeaturingaprofilecorrespondingtotheoneinFig.8
onpage25,ref.a(“S”profile).
Table5referstothebalancespringforbarlengthsequaltoorlongerthan5mandfeaturingaprofilecorrespondingtotheoneinFig.8on
page25,ref.b(“L”profile).
ThekeytosymbolsforidentifyingthefixingholesbasedonthenumberindicatedinthetablesisshowninFig.30.