4.
MACHINE PARAMETERS
Axis parameters
(SOFT M: V15.3X)
(S
OFT T: V16.3X)
·126·
When the machine uses semi-absolute scales (with coded marker pulses), the axis may be homed
anywhere within its travel. Thus, this parameter must only be set when applying leadscrew error
compensation. The amount of leadscrew error of the machine reference point may have any value.
MAXVOLT (P37)
Defines the value of the velocity command corresponding to the maximum feedrate of the axis
indicated by a.m.p. G00FEED (P38).
G00FEED (P38)
Indicates the maximum feedrate G00 (rapid traverse) of this axis.
UNIDIR (P39)
Indicates the direction of the unidirectional approach in G00 moves.
OVERRUN (P40)
Indicates the distance to be kept between the approach point and the programmed point. If it is a
Lathe model, this distance must be in radius.
UNIFEED (P41)
Indicates the feedrate to be used from the approach point to the programmed point.
Possible values
Integer numbers between 0 mV and 9999 mV.
Default value: 9500 (9.5 V)
Possible values
Between 0.0001 and 199999.9999 degrees/min or mm/min.
Between 0.00001 and 7874.01574 inches/min.
Default value: 10000 mm/min.
Value Meaning
+ sign Positive direction.
- sign Negative direction.
Default value: + sign
Possible values
Between 0.0001 and 99999.9999 degrees/min or mm/min.
Between 0.00001 inches/min and 3937.00787 inches/min.
Default value: 0 (not unidirectional)
Possible values
Between 0.0001 and 99999.9999 degrees/min or mm/min.
Between 0.00001 inches/min and 3937.00787 inches/min.
Default value: 0