Remote modules. RIO5, RIOW and RIOR series.
CNCelite
8058 8060
8065 8070
RIOR-E-48I32O / RIOR-E-48I32O-ANALOG (ETHERCAT).
Specifications.
ꞏ103ꞏ
REF. 2107
Inputs/outputs. RIOR-E-48I32O
- 48 DI (24 V DC).
- 32 DO (24 V DC, 250 mA, 1H).
RIOR-E-48I32O-ANALOG
- 48 DI (24 V DC).
- 32 DO (24 V DC, 250 mA, 1H).
- 2 AI configurable to voltage or current.
(if configured to voltage; 12 bits, ±10 V).
(if configured to current; 12 bits, ±20 V).
- 4 AO (16 bits, ±10 V).
- 2 PT100 (12 bits, -200 to 850 ºC range, (-328 to 1562 ºF) 0.1 ºC resolution).
Type. Description.
Do not touch or handle exposed parts of equipment (boards, circuits, etc). Only personnel authorized
by Fagor Automation may handle the exposed parts of the equipment.
Do not make any connections when the module is powered. Disconnect the power to the module before
making a connection.
Do not connect the module to a power supply that is turned on. Before connecting the module, turn
the power supply off by unplugging the power cable.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fagor CNC 8058elite T and is the answer not in the manual?

Fagor CNC 8058elite T Specifications

General IconGeneral
BrandFagor
ModelCNC 8058elite T
CategoryControl Unit
LanguageEnglish

Related product manuals