Remote modules. RIO5, RIOW and RIOR series.
CNCelite
8058 8060
8065 8070
RIOR-E-48I32O / RIOR-E-48I32O-ANALOG (CANOPEN).
5.
ꞏ85ꞏ
REF. 2107
5 RIOR-E-48I32O / RIOR-E-48I32O-ANALOG (CANOPEN).
Remote modules may be used to have an additional number of digital and analog inputs and
outputs (remote I/O) that placed in the cabinet, permit controlling various devices of the
machine.
RIOR remote modules, for CANopen bus.
Each RIOR module constitutes a node inside the CAN bus, which may have up to 32 nodes,
including the central unit and the keyboards. RIOR modules can communicate at 1 MHz up
to 20 meters. The following RIOR modules are available.
Module Description.
RIOR-48I32O 48 digital inputs.
32 digital outputs.
RIOR-48I32O-ANALOG 48 digital inputs.
32 digital outputs.
2 Analog inputs (12 bits that may be configured in voltage or current).
4 Analog outputs (16 bits in voltage).
2 PT100 inputs.