Remote modules. RIO5, RIOW and RIOR series.
CNCelite
8058 8060
8065 8070
5.
RIOR-E-48I32O / RIOR-E-48I32O-ANALOG (CANOPEN).
ꞏ86ꞏ
REF. 2107
CANopen bus characteristics.
When the CNC works with CANopen bus, this bus lets combine in the bus groups (nodes)
formed by the RIO5, RIOW and RIOR series modules; modules of different series cannot
be combined in the same group. The maximum number of inputs and outputs available at
the CANopen bus is the following.
Type of input/output Amount.
Digital inputs. 1024
Digital outputs. 1024
General purpose analog inputs. 40
Analog outputs. 40
Analog inputs for temperature sensors. 10