4. Error types>
25
E14 QC1 Blocked
(Only gas ovens)
Chamber ignition control blocked. This
error is generated when the chamber
burner does not light after 3 attempts.
The oven is completely disabled.
E15 QC1 Fault
(Only gas ovens)
Fault in the ignition box due to one of
these 2 errors:
EV gas is not activated.
The box cannot be unlocked.
The oven is completely disabled.
E16 QV Blower Fault
(Only gas ovens)
Steam blower error.
Can only be operated in
Convection mode.
E17 QV Blocked
(Only gas ovens)
Steam ignition control blocked. This error
is generated when the steam burner does
not ignite after three attempts.
Can only be operated in
Convection mode.
E18 QV Fault
(Only gas ovens)
Fault in the boiler ignition box due to 2
errors:
EV gas is not activated.
The box cannot be unlocked.
Can only be operated in
Convection mode.
E19 QC2 Blower Fault
(20-tray gas ovens only)
QC2 chamber blower error.
The oven is completely disabled.
E20 QC2 Blocked
(20-tray gas ovens only)
Chamber ignition control blocked. This
error is generated when the chamber
burner does not light after 3 attempts.
The oven is completely disabled.
E21 QC2 Fault
(20-tray gas ovens only)
Fault in the ignition box due to one of
these 2 errors:
EV gas is not activated.
The box cannot be unlocked.
The oven is completely disabled.
E22 COM Error
Communication error between cards.
The oven is completely disabled.
E23 Autotest Error
(Only CP and CPW)
The value of the thermocouple has not
stabilised within 15 minutes during the
autotest cycle (TC).
Autotest error message.
E24 Calibration Error
(Only CP and CPW)
The value of the thermocouple has not
stabilised within 15 minutes during the
calibration cycle (TC and TN1).
Calibration error message.
E25 Flow Meter Error
(Only CP and CPW)
A level is reached during filling after the
automatic emptying process but the flow
meter does not detect the level.
Flow meter error message.
E26 Level Error
(Only CP and CPW)
The flow meter counts more litres than it
should and no level is detected when
filling after the automatic emptying
process.
Can only be operated in
Convection mode.
E27 Boiler Error
(Only CP and CPW)
VDV has been active longer than it should
be in either of the two TG cooling
systems.
Can only be operated in
Convection mode.
E28 Detergent Pressure
Switch Error
(Only liquid detergent
kit)
The pressure switch detects that the hose
is obstructed during the dosing of liquid
detergents.
Only solid detergent can be used
for washing.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fagor CONCEPT and is the answer not in the manual?

Fagor CONCEPT Specifications

General IconGeneral
Oven typeElectric
Number of ovens1
Built-inYes
Voltage220-240 V
ColorStainless steel
Frequency50 Hz

Related product manuals