Hardware
MP-70/50 • MP-72/52 • MP-73/53 • PN 98-0002-29 • REV 1709.13 11
OPTIONAL HAND SWITCHES (MP-70 ONLY)
Fair-Play offers the following optional hand switches for use with the MP-70/72
only.
Shot timer (domestic usage)
Shot timer - for FIBA basketball rules
When connecting a wired hand switch, refer to the drawing MP-70 AND MP-50
BACK PANEL VIEWS on page 10. In some cases, you can connect more than one
hand switch to the MP-70/72 to at a time. The HC-70 and HH-70 hand switches
listed above include a nine-pin adaptor, allowing you to connect another hand
switch in a daisy-chain configuration.
TO ENABLE OR DISABLE MICLOCK™ REMOTE SWITCH
MiClock™ Wireless G2 Game Clock Remote model MC-10 is compatible only to
MP-72-2211 or MP-72-2213 (firmware version 2.25 or greater).
Note: Older wireless MP-70 or MP-72 models can be exchanged or upgraded at
the factory. Compatibility with MiClock requires wiring modifications and
firmware upgrades to the MP-72 (version 2.25+) and firmware upgrade to
the Wireless G2 transmitter.
1. The MP-72, MiClock™ and the scoreboard receiver must be set to the
same RF channel.
a. For MP-72 refer to SCOREBOARD OPERATION (G2) on page 104.
b. For MiClock refer to FACTORY SETTINGS of the MICLOCK QUICK
REFERENCE Guide PN 98-2008-02.
2. Turn ON the MP-72.
3. Set the TIME IN-OUT switch to TIME OUT position.
4. Hold down the Shift key while pressing the 1 key. The bottom line of the
LCD displays “MiClock ON? Y/N”.
a. Press 4 (Y) to use only the MiClock Remote Switch and disable MP-
72 TIME IN-OUT Switch, or
b. Press 6 (N) to use only the MP-72 TIME IN-OUT switch.
5. To reset the Game Clock, refer to CLOCK SET KEY on page 14.