EasyManuals Logo

Festo CMMP-AS-***-M3 Series User Manual

Festo CMMP-AS-***-M3 Series
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #111 background imageLoading...
Page #111 background image
5 Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English 111
Index 6065
h
Name following_error_window
Object Code VAR
Data Type UINT32
Access rw
PDO mapping yes
Units position units
Value Range
Default Value 9101 (9101/65536 R = 50°)
Object 6066
h
: following_error_time_out
If a contouring error longer than defined in this object occurs, the related bit 13 following_error is set in
the statusword.
Index 6066
h
Name following_error_time_out
Object Code VAR
Data Type UINT16
Access rw
PDO mapping yes
Units ms
Value Range 0 … 27314
Default Value 0
Object 60F4
h
: following_error_actual_value
The current contouring error can be read out via this object. This object is specified in user-defined
increments.
Index 60F4
h
Name following_error_actual_value
Object Code VAR
Data Type INT32
Access ro
PDO mapping yes
Units position units
Value Range
Default Value

Table of Contents

Other manuals for Festo CMMP-AS-***-M3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CMMP-AS-***-M3 Series and is the answer not in the manual?

Festo CMMP-AS-***-M3 Series Specifications

General IconGeneral
Power Supply24 V DC
Communication InterfacesEtherCAT, CANopen
Safety FunctionsSTO (Safe Torque Off)
Number of axes1
Protection ClassIP20
Control ModePosition, Velocity, Torque Control
FeedbackEncoder, Resolver
Ambient Temperature Range0 to 40 °C
Relative Humidity5% to 95% (non-condensing)
Storage Temperature Range-25 ... +70 °C