7 Operating modes
216 Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Access ro
PDO mapping yes
Units motor_rated_torque/1000
Value Range
Default Value
Object 6078
h
: current_actual_value
By means of this object, the motor's actual current can be read out in thousandths of the nominal cur
rent (object 6075
h
).
Index 6078
h
Name current_actual_value
Object Code VAR
Data Type INT16
Access ro
PDO mapping yes
Units motor_rated_current/1000
Value Range
Default Value
Object 6079
h
: dc_link_circuit_voltage
The intermediate circuit voltage of the controller can be read via this object. The voltage is specified in
the unit millivolts.
Index 6079
h
Name dc_link_circuit_voltage
Object Code VAR
Data Type UINT32
Access ro
PDO mapping yes
Units mV
Value Range
Default Value

Table of Contents

Other manuals for Festo CMMP-AS-***-M3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CMMP-AS-***-M3 Series and is the answer not in the manual?

Festo CMMP-AS-***-M3 Series Specifications

General IconGeneral
Power Supply24 V DC
Communication InterfacesEtherCAT, CANopen
Safety FunctionsSTO (Safe Torque Off)
Number of axes1
Protection ClassIP20
Control ModePosition, Velocity, Torque Control
FeedbackEncoder, Resolver
Ambient Temperature Range0 to 40 °C
Relative Humidity5% to 95% (non-condensing)
Storage Temperature Range-25 ... +70 °C