Electrical connection
Flexible conductor cross section with wire end sleeve with plastic
sleeve
0.25 … 1.5 mm
2
Strip length 10 mm
Tab. 95: Electrical connection
10.4 Operating and environmental conditions
CMSH-...
1)
Ambient temperature -40 … 80 °C
Note on ambient temperature Indicated on display at operating temperature -30 … 80 ° C
Climatic class during transport Climate class 2K4 in accordance with DIN EN 60721-3-2,
ambient temperature range -40 … 80 °C
Climate class in operation Climate class 4K3 in accordance with DIN EN 60721-3-4,
ambient temperature range -40 … 80 °C
Climatic class during storage Climate class 1K5 in accordance with DIN EN 60721-3-1,
ambient temperature range –40 … 80 °C
Degree of protection IP66/IP67 in accordance with IEC 60529
Shock resistance Shock test with severity level 2 in accordance with EN 60068-2-29
Vibration resistance Transport application test with severity level 2 in accordance with
EN 60068-2-6
Pollution degree 3
EMC conformity NAMUR recommendation NE 21
Maximum altitude for operation < 2000 m
Overvoltage category II in accordance with IEC/EN 61010-1
CE marking
è
www.festo.com/sp
1) All product variants
Tab. 96: Operating and environmental conditions
10.5
Materials
CMSH-...
Material housing Die-cast aluminium, polyester coating
Material of the inspection
window
PC
Material of the screws High-alloy stainless steel