2. Commissioning
2-24
Festo P.BE-CPX-FB32-EN en 1111a
3. Assign the instances of the Assembly O bject:
Instance 101:Inputs
Instance 100:Outputs
Instance 102: Configuration data, if used
(“Configuration Assembly”)
4. Select the data format SINT.
5. Enter the IP address, if necessary.
2.2.3 Set up a listen-only connection
When the station features have been configured
(e.g. by installatio n of the EDS file), the follow ing steps are
required for parameterisati o n (depending o n the
configuration program):
1. Install your CPX terminal and set the network addressing
according to section 1.3.3.
2. Create a connection to an EtherNet/IP station.
With RSLogix, use for this the profile
Generic Ethernet Device ”.
3. Assign the instances of the Assembly O bject:
Instance 101:Inputs
Instance 1 Outputs
Instance 102: Configuration data, if used
(“Configuration Assembly”)
4. Select the data format Input Data SINT.
5. Enter the IP address, if necessary.