1. Installation
1-18
Festo P.BE-CPX-FB32-EN en 1111a
1.3.4 Extended Ethernet settings
Via the “Ethernet Link Object” (see appendix B.2.3), you can
undertake additional settings for the Ethernet connection.
Configure the Ethernet Link Object via your EtherNet/IP
Master or scanner. The extended Ethernet settings are
described in the following.
Automatic setting (factory setting)
It is standard for the fieldbus baud rate and the Duplex mode
to be recognised automatically by the CPX-FB32.
Baud rate
The field bus baud rate can be switched via EtherNet/IP and
is set via Attribute no. 6 (Interface Speed) of the Ethernet Link
Object. The follow i ng settings are possible:
–10MBd
– 100 MBd
Duplex mode
The full Duplex mode can be activated/deactiv ated.
1.3.5 Use Webserver fun c tions of the CPX-FB32
A Webserver is integrated in the CPX-FB32. The Webserver
makes available read access to the most important
parameters and diagnostic functions.