180
Practical information
Standard charging, mode 2
Domestic socket
(standard charging - alternating current (AC))
Mode 2 with a standard socket: 8 A maximum
charging current.
Mode 2 with a Green'Up socket: 16 A
maximum charging current.
To have this type of socket installed, call a
professional installer.
Specic domestic charging cable - mode
2 (AC)
Identication label C on the charging
connector (vehicle side).
Specic domestic charging cable
(mode 2)
You must not damage the cable.
In the event of damage, do not use it and
contact a Fiat Dealership or a qualied
workshop to replace it.
Control unit (mode 2)
POWER
Green: electrical connection established;
charging can begin.
CHARGE
Flashing green: charging in progress or
temperature pre-conditioning activated.
Fixed green: charging complete.
FAULT
Red: fault; charging not permitted or must
be stopped immediately. Check that everything
is connected correctly and that the electrical
system is not faulty.
If the indicator lamp does not go o󰀨, contact a
Fiat Dealership or a qualied workshop.
Upon plugging the charging cable into a
domestic socket, all of the indicator lamps come
on briey.
If no indicator lamps come on, check the
domestic socket's circuit-breaker:
If the circuit-breaker has tripped, contact a
professional to check that the electrical system
is compatible and/or carry out any necessary
repairs.
If the circuit-breaker has not tripped, stop
using the charging cable and contact a Fiat
Dealership or a qualied workshop.
Control unit label - Recommendations
Refer to the handbook before use.
1. Incorrect use of this charging cable may
result in re, property damage and serious
injury or death by electrocution!
2. Always use a correctly earthed power
socket, protected by a 30 mA residual
current device.
3. Always use an electrical socket protected
by a circuit-breaker appropriate for the
electrical circuit’s current rating.
Fiat.K0-Fiat-VP.2021.01.en-GB.indb 180 14/02/2022 15:33:45