MNL004_EN rev. F
Pag. 51 di 56
VISUAL AND ACOUSTIC ALARM
SOLUTION
COMPRES WORK.
Air condition the environment.
Clean the condenser (see par. 6.3)
Check that installation has been properly performed (see par. 4.2)
Switch-off the equipment from keypad (see par. 5.2.3.1) and then,
switch it on again.
Check that door is properly closed.
DEFROST TIME
Switch-off the equipment from keypad (see par. 5.2.3.1) and then,
switch it on again.
Check ambient conditions (environment should be neither too hot
nor too cold).
Check that installation has been properly performed (see par. 4.2)
If the problem persists, contact Technical Support.
HIGH TEMP alarm
Check that products have been correctly stored in the chamber (see
par. 4.6.3)
Check ambient conditions (environment should be neither too hot
nor too cold).
Clean the condenser (see par. 6.3)
Check that door is properly closed.
Air condition the environment.
LOW TEMP alarm
Contact Technical Support.
POWER FAIL HT
Check the alarms list.
Check the electrical system or accidental disconnection of the plug.
H 00:m00
Replace button battery on electronic board.
NO BATTERY (only if DMLP
Digital Monitor is installed)
Replace the battery.
BATTERY FAILURE (only if DMLP
Digital Monitor is installed)
Replace the battery.
PROBE S1-S2-S3-S4
Contact Technical Support. Refrigerator functioning is guaranteed
anyway.

Table of Contents