July 2013
251
Figure 8‐1. Terminal Box of Natural Gas Certified
FIELDVUE DVC6200f Digital Valve Controller
GAS‐BLOCKING
PRESS‐FIT ADAPTOR
WIRING CONNECTOR
W9923‐1
Key Description Part Number
Module Base
(see figure 8‐2 and 8‐4)
DVC6200f and DVC6205f
  2 Module Base
(6)
 11 Drive Screw
(6)
(2 req'd)
 12 O‐ring
(1)
 19 Label, Shield Assembly
(6)
61 Pipe Plug, hex socket
(6)
(3 req'd)
243 Slotted Pin (flame arrestor)
(6)
(3 req'd)
I/P Converter Assembly
(see figure 8‐2 and 8‐4)
DVC6200f and DVC6205f
 23 Cap Screw, hex socket, SST
(2)(8)
(4 req'd)
 39* O‐ring
(1)(3)(5)
 41 I/P Converter
(5)
169 Shroud
(5)(8)
(not shown, see figure 7‐4)
210* Boot, nitrile
(1)(5)
(2 req'd) (see figure 7‐4)
231* Seal Screen
(1)(3)(5)
Key Description Part Number
Relay (see figure 8‐2 and 8‐4)
DVC6200f and DVC6205f
24* Relay Assembly, (includes shroud, relay seal, mounting screws)
 Standard (nitrile elastomers)
Standard Bleed
Housing A (used for GX actuator)
   Single‐/acting direct (relay C) 38B5786X182
   Single‐acting reverse (relay B) 38B5786X172
Housing B (used for all actuators except GX)
   Single‐acting direct (relay C) 38B5786X132
   Double‐acting (relay A) 38B5786X052
   Single‐acting reverse (relay B) 38B5786X092
  Low Bleed
  Housing A (used for GX actuator)
   Single‐acting direct (relay C) 38B5786X202
   Single‐acting reverse (relay B) 38B5786X192
  Housing B (used for all actuators except G)
   Single‐acting direct (relay C) 38B5786X152
   Double‐acting (relay A) 38B5786X072
   Single‐acting reverse (relay B) 38B5786X112
 Extreme Temperature option (fluorosilicone elastomers)
Standard Bleed
    Single‐acting direct (relay C) 38B5786X142
    Double‐acting (relay A) 38B5786X032
    Single‐acting reverse (relay B) 38B5786X102
  Low Bleed
    Single‐acting direct (relay C) 38B5786X162
    Double‐acting (relay A) 38B5786X082
    Single‐acting reverse (relay B) 38B5786X122
Loop Connections Terminal Box
(see figure 8‐2 and 8‐4)
DVC6200f and DVC6205f
  4 Terminal Box Cap
 34* O‐ring
(1)(4)
 36* O‐ring
(1)(4)
 58 Set Screw, hex socket, SST
(2)
 72 Cap Screw, hex socket, SST
(2)
164 Terminal Box Assembly
*Recommended spare
1. Available in the Elastomer Spare Parts Kit
2. Available in the Small Hardware Spare Parts Kit
3. Available in the Seal Screen Kit
4. Available in the Terminal Box Kit
5. Available in the I/P Converter Kit
6. Available in the Spare Module Base Assembly Kit
8. Available in the Spare Shroud Kit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fisher FIELDVUE DVC6200f and is the answer not in the manual?

Fisher FIELDVUE DVC6200f Specifications

General IconGeneral
BrandFisher
ModelFIELDVUE DVC6200f
CategoryController
LanguageEnglish

Related product manuals