19 Advanced functions
19.7 Event triggers FLUXUS H721
2022-05-15, UMFLUXUS_H721V1-5EN
186
Afterwards the properties of the event trigger are defined.
Totalizers Operating volume (+) totalizer for the volumetric flow rate in positive flow direction
Operating volume (-) totalizer for the volumetric flow rate in negative flow direction
Operating volume (Δ) difference of the totalizers for the positive and negative flow direction
Standard volume (+) totalizer for the standard volumetric flow rate in positive flow direction
Standard volume (-) totalizer for the standard volumetric flow rate in negative flow direction
Standard vol. (Δ) difference of the totalizers for the positive and negative flow direction
Mass (+) totalizer for the mass flow rate in positive flow direction
Mass (-) totalizer for the mass flow rate in negative flow direction
Mass (Δ) difference of the totalizers for the positive and negative flow direction
Fluid properties Fluid temp. fluid temperature
Fluid pressure fluid pressure
Fluid density fluid density
Kin. viscosity kinematic viscosity
Dyn. viscosity dynamic viscosity
Norm. density density of the reference temperature
Diagnostic values Amplitude signal amplitude
Quality signal quality
SNR ratio useful signal/noise signal
SCNR ratio of useful signal and correlated noise signal
VariAmp amplitude fluctuation
VariTime transit time fluctuation
Amplification amplification, important to receive a useful signal
Pig detection signalizes whether a pig is detected
This display will only be indicated if Pig detection is activated.
HPI measurement API gravity scale value, that derives from the density at standard conditions
Volume corr. factor volume correction factor
Current fluid number of the detected fluid
Δ API gravity absolute change of the HPI property per set time base for the fluid change
Miscellaneous Custom. Input 1 measured values of input quantities (e.g., temperature, density) which are
not used for calculation
In the menu item Options\Assign inputs it is possible to assign
configured inputs to customized inputs.
Custom. Input 2
Custom. Input 3
Custom. Input 4
Sound speed Sound speed sound speed
Sound speed (Δ) absolute change of the measured sound speed per set time base for the
fluid change
Tab. 19.4: Source item
source item list item output