14 Outputs (TF7-*721**-******-******a-*****-**; a = U, V, D)
FLUXUS H721 14.1 Configuration of a binary output
149
UMFLUXUS_H721V1-5EN, 2022-05-15
14 Outputs (TF7-*721**-******-******a-*****-**; a = U, V, D)
If the transmitter is equipped with outputs, they have to be
configured. For the configuration of the analog output, see
section 9.3.6.
The transmitter can also be equipped with binary outputs.
A binary output switches if one of the following switching
conditions is met:
the measured value exceeds or falls below a limit
the measured value lays within or outside a defined range
a measurement is not possible
an event occurs
14.1 Configuration of a binary output
Assignment of an output
Select the channel in the program branch Options (here: Channel A).
Press ENTER.
This display will not be indicated if the transmitter has only one measuring channel.
Select the list item Outputs.
Press ENTER.
Select the output to be assigned to the channel.
Press ENTER.
If the channel has already been assigned to a channel, it is displayed as follows: Binary B1 (A).
•Select Yes to change the settings for an already assigned output or to assign a new output.
•Select No to cancel the assignment and to return to the previous menu item.
Press ENTER.
Options
Channel x
Outputs
Select output
Enable output
Source item
see annex A
Options\Channel A
Options\Channel A\Outputs\Binary B1(--)
Options\Channel A\Outputs\Binary B1\B1 Enable