7.2 IR Thermal Imaging Specifications 
Detector type      FLIR LeptonTM; Micro-bolometer Focal Plane Array (FPA) 
Thermal Sensitivity     150mK 
IR Imaging resolution    60 x 80 pixels  
IR Imaging field of view    50.0 o x 38.6 o (vertical x horizontal) 
IR Imaging spectral response    8 to 14μm 
IR Image Capture Frequency    9Hz 
IR Image Color Palettes    Programmable: Iron, Rainbow, and Gray scale 
Shutter        Integrated, automatic shutter 
Laser Pointer      Class I (red) 
IR Temperature Measurement range  14°F ~ +302°F (-10°C ~ +150°C) 
Over- and under- range indication  OL 
Temperature reading stabilization   Dashes are displayed for approximately 30 seconds as 
temperature reading stabilizes 
IR Temperature Resolution    0.1°F (0.1°C) 
IR Temperature Accuracy  5.4°F (±3°C) or ± 3% of reading; whichever is greater (after 
2-minute warm-up period) 
Distance to Spot (D:S) ratio    30:1 
Temperature Scanning    Continuous 
Emissivity      4 presets plus a custom setting (0.10 to 0.99) 
Targeting       Displayed Cross hairs pinpoint center of measurement spot