FLI R Duo User Guide
436-0100-01-10, Rev. 200 Duo User Guide
Information on this page is subject to change without notice
51
3.2 Time synchronization
Time synchronization for other systems to synchronize the camera time.
Request instruction
Instruction Application: UART /
TCP
Data flow: G / A --- CS
Identification
code
1 Byte
status code
1 Byte
Instruction number
2 Bytes
Instruction length
2 Bytes
CRC1
/ reserved
2 Bytes
0x64
0x00
0x0002
0x08
CRC
Instruction body
8 Bytes
CRC2
/ reserved
2 Bytes
Instruction body format:
Struct {
String strD ateTime [20] ; // DT time format, such as 20 17 - 01 - 01 0 1 :
0 1 : 01
};
CRC
CRC Description:
In CSP-TCP applications, the CRC is ignored
Response command:
Instruction Application: UART /
TCP
Data flow: CS --- G / A
Identification
code
1 Byte
status code
1 Byte
Instruction number
2 Bytes
Instruction length
2 Bytes
CRC1
/ reserved
2 Bytes
0x64
Status Code
0x0003
0x00
CRC
Instruction body
0 Bytes
CRC2
/ reserved
2 B ytes
air
CRC
CRC Description:
In CSP-TCP applications, the CRC is ignored