FLI R Duo User Guide
436-0100-01-10, Rev. 200 Duo User Guide
Information on this page is subject to change without notice
64
In CSP-TCP applications, the CRC is ignored
3.9.2 formatting
Format the specified SD card.
Request instruction
Instruction Application: UART /
TCP
Data flow: G / A --- CS
Identification
code
1 Byte
status code
1 Byte
Instruction number
2 Bytes
Instruction length
2 Bytes
CRC1
/ reserved
2 Bytes
0x64
0x00
0x1016
0x04
CRC
Instruction body
4 Bytes
CRC2
/ reserved
2 Bytes
Instruction body format:
Struct {
uint8_t u8SDcardNo; // SD card number, from 1 to start
Byte Reserve [3]; // Reserved
};
CRC
CRC Description :
In CSP-TCP applications, the CRC is ignored
Response command:
Instruction Application: UART /
TCP
Data flow: CS --- G / A
Identification
code
1 Byte
status code
1 Byte
Instruction number
2 Bytes
Instruction length
2 Bytes
CRC1
/ reserved
2 Bytes
0x64
Status Code
0x1017
0x00
CRC
Instruction body
0 Bytes
CRC2
/ reserved
2 Bytes