432-0003-00-10 Rev 150 M-Series Operators Manual 23
CHAPTER 3 M-Series System Startup
System Startup and Shutdown
The M-Series camera does not have an on/off switch. Instead, its power state is
controlled by the JCU (or a PC, if you choose to set up that interface). Generally,
the camera is never completely off but in a standby state waiting for a “wake”
command from the JCU.
Typically, the M-Series system is connected to its power source through a circuit
breaker, which functions as the primary on/off switch for the system. Should it be
necessary for some reason to completely shut down the system, the circuit
breaker is used. In normal operation, however, the camera will have power and
will be in one of three states or modes:
Bootup, or powering on
Powered on, or fully functional
Standby, a low-power state waiting for a wake command
The Bootup Process
The bootup process is slightly different depending on whether the system had
been completely turned off or is being wakened from a standby state. Most of
what happens, however, is the same.
If you are starting from a full shutdown, make sure your monitor is turned on. Then
power on the system. When power from the circuit breaker is initially applied to
the system, the camera will perform a short pan/tilt initialization by rotating back
and forth and tilting up and down and then begin a bootup sequence.