Screening alarm
21
21.1 General
The screening alarm can be used, for example, at airports to detect passengers with ele-
vated body temperatures, which may indicate the presence of a fever.
The screening alarm can also be used to detect temperature anomalies in a series of in-
spected objects in a similar/fixed setup.
Activating the screening mode will turn on a measurement box and screening data in the
result table.
The sampled average temperature.
The alarm temperature.
The measured temperature.
The alarm will trigger when the measurement box measures a temperature higher than the
alarm temperature. The alarm temperature is, in turn, the sum of a specified allowed devia-
tion and a sampled average value.
WARNING
Make sure that the laser is disabled when you point the camera at the face of a person. The laser beam
can cause eye irritation. Disable the laser by selecting
(Settings) > Device settings > Lamp & laser >
Disable all.
21.2 Procedure
Follow this procedure:
1. Enable the screening mode by selecting
(Settings) > Device settings > User inter-
face options > Screening mode = On.
2. Push the navigation pad to display the menu system.
3. Select
(Recording mode) and push the navigation pad. This displays a submenu.
4. Select
(Screening).
5. Push the navigation pad. This displays a dialog box where you can define the settings
for the alarm:
Allowed deviation: The allowed deviation from the sampled average.
Alarm sound: Applicable values are Beep or No sound.
6. Push the navigation pad. This closes the dialog box.
7. Aim the camera toward a point of interest. The object should be within the frame of the
measurement box.
8. To reset the sampled average, push and hold the programmable button
above the
screen.
9. To sample, push the programmable button
above the screen.
#T810253; r. AA/42549/42549; en-US
92

Table of Contents

Other manuals for FLIR T530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR T530 and is the answer not in the manual?

FLIR T530 Specifications

General IconGeneral
Resolution320 x 240 pixels
Thermal Sensitivity< 30 mK
Digital Zoom1-4x continuous
Image ModesThermal, MSX, Picture-in-Picture
StorageSD card
Image Frequency30 Hz
Accuracy±2°C or ±2% of reading
Digital Camera5 MP
Laser Distance MeterYes
Wi-FiYes
Video RecordingYes
Video OutputHDMI
Minimum Focus Distance0.15 m (0.49 ft)
Operating Temperature Range-15°C to 50°C (5°F to 122°F)
Storage Temperature Range-40°C to 70°C (-40°F to 158°F)
Temperature Range0°C to +650°C
Field of View24° × 18°
Display4-inch LCD touchscreen
Battery LifeApprox. 4 hours
FocusContinuous, one-shot contrast, manual
Spectral Range7.5-14 µm
Weight1.3 kg (2.9 lbs)
ConnectivityWi-Fi, USB
Lens Options14°, 24°, 42°

Related product manuals