45
Response details
K:
S
K
040,
E382AB
E383A1
E383A9
EFBC91
Source
Kanji
Channel 65
K:
S
K
044,
Source
Kanji
Channel 69
(Empty)
K:
S
K
047,
E382B5
E383BC
E38390
E383BC
EFBCA1
Source
Kanji
Channel 72
4-3-4. CPU Status Request Command (8)
This command allows you to indicate which CPU is active in the MFR main unit.
Command format
Control command
Command response
@[sp]A?
@[sp]A:<ID>
Control command
BYTE No.
1
2
3
4
Command
@
[sp]
A
?
Command response
BYTE No.
1
2
3
4
5
Response
@
[sp]
A
:
<ID>
<ID>: Unit ID number (01-FE)
Command Response
There are two response types whether the CPU is active or passive state.
If the CPU is active:
Response
@ A?
Echo
A:A
Unit ID number is 10 (0x0A)
New line
>
Prompt