4-3-6. System Size Request Command (10)
F? Commands allow you to obtain MFR-1616/ MFR-1616R/ MFR-3216/ MFR-3216RPS/
MFR-3232/ MFR-3232RPS system size. (MFR-1616A not supported.)
Command Format
Command
Command response
@[sp]F?<Lvl>
F:<Lvl><Dst Size>,<Src Size>/< Dst Size >,<Src Size>
Commands
BYTE No.
1
2
3
4
5
Command
@
[sp]
F
?
<Lvl>
Command response
BYTE No.
1
2
3
4
5
6
7
8
9
10
Response
F
:
<Lvl>
<Dst Size>
,
<Src Size>
/
<Dst Size>
,
<Src Size>
<Dst Size>: Destination channel number
<Src Size>: Source channel number
Command Example
Response
@ F?0
Echo
F:0FF,FF/FF,FF
256 destination / 256 source channel numbers.