Operation manual P328S
16
© 2018 FROMM Holding AG
All rights reserved. Reproduction and duplication - also in extracts - are not permitted.
7.4 Strap Database
To open the strap database, press the strap database key in the adjustment menu.
The strap database stores the data for various plastic straps.
The user can save user-defined data sets.
20 data sets are possible:
Data set 01: no strap assigned, T:50% (tension)/ W:50% (welding time) are defined.
Data sets 02-10: FROMM standard straps
Data sets 11-20: User-defined data sets
The data sets 01-10 cannot be overwritten or deleted.
The active data set is displayed on the strap database key.
When delivered, last data set used in the outgoing inspection is active.
The data set 01 (default) is displayed.
Tap to open the strap database menu.
7.4.1 Select data set
Key settings
Tap - return to the adjustment menu.
Shift key mm/inch
The active setting is displayed in green.
Tap - change between metric and inch systems.
Save key / Delete key
The save key or delete key is only displayed when the corresponding function is active.
See 7.4.2 Save Data Set / 7.4.3 Delete Data Set
OK key
The OK key only appears when this function is active.
Tap - activate the highlighted data set.
- After 2 seconds, return to the adjustment menu.
Selection key
Tap - change to previous data set.
Selection key
Tap - change to next data set.
The selection keys show:
Line 1: Data set no. / strap name
Line 2:
(data set active) / T:35% (tension) / W:55% (welding time)
Line 3: Strap dimensions (width x thickness)
Line 4: FROMM part number
Lines 5-7: Preview of the next data set