Activating/deactivating the safety function
Safety function
for immediate
stop, dependent
on an external
device
Die BIAS 300 Plasma has a safety function, which, dependent on an external de-
vice or control, immediately switches off the power source.
The external device or the control transmits a signal to the power source via fibre
optic cables: If the fibre optic input „Arc In“ on the power source is lit up, this
indicates that the external device or control is ready.
When the light goes out, the safety function of the power source immediately
switches off. As soon as the fibre optic input „Arc In“ lights up again, operation of
the BIAS 300 Plasma power source can resume.
The safety function is activated or deactivated by jumper X15 on the MM_ARC
PCB inside the power source.
Safety
WARNING!
Danger from incorrect work that is not carried out properly.
This can result in serious personal injury and damage to property.
The following activities must only be carried out by trained and qualified per-
sonnel! Follow the safety rules.
WARNING!
Danger from electrical current.
This can result in serious personal injury and damage to property.
Before starting work, switch off all devices and components involved and dis-
connect them from the grid.
Secure all devices and components involved so they cannot be switched back
on.
After opening the device, use a suitable measuring instrument to check that
electrically charged components (such as capacitors) have been discharged.
WARNING!
Danger due to insufficient ground conductor connection.
This can result in serious personal injury and damage to property.
The housing screws provide a suitable ground conductor connection for
grounding the housing.
The housing screws must not under any circumstances be replaced by other
screws without a reliable ground conductor connection.