Technical data
Special voltages
NOTE!
Incorrectly rated mains plugs, mains leads or fuses can result in serious dama-
ge. If the device is designed for a special voltage, the technical data on the ra-
ting plate apply. The mains plug, mains lead and their fuse protection must be
rated accordingly.
Technical Data -
BIAS 300 Plas-
ma
Mains voltage 3 x 400 V
Mains voltage tolerance +/- 15 %
Mains fuse protection (slow-blow) 3 x 32 A
Primary continuous power 15,9 kVA
Cos phi 0,99
Efficiency 91 %
Stepless operating current area 0 - 60 A
Operating temperature 0 °C - 40 °C
32 °F - 104 °F
Max. output voltage 300 V
Working voltage 0 - 8 V high resistance
>8 - 300 V
Arc reaction time
1)
7 μs.
Max. output power 10 kW
Duty cycle 100 100 % / 40 °C
Max. output current 60 A
Protection IP 21
Type of cooling AF
Insulation class F
Dimensions (power source with inter-
face) l x w x h
750 x 310 x 700 mm
29.5 x 12.2 x 27.6 in.
Weight 45 kg
99.21 Ib.
Marks of conformity CE
1)
Arc reaction time from detection of overcurrent until the voltage of the cur-
rent connection is switched off (+)
63