EasyManua.ls Logo

Fronius BIAS 300 Plasma - Technical Data; Special Voltages; BIAS 300 Plasma Specifications

Fronius BIAS 300 Plasma
68 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Special voltages
NOTE!
Incorrectly rated mains plugs, mains leads or fuses can result in serious dama-
ge. If the device is designed for a special voltage, the technical data on the ra-
ting plate apply. The mains plug, mains lead and their fuse protection must be
rated accordingly.
Technical Data -
BIAS 300 Plas-
ma
Mains voltage 3 x 400 V
Mains voltage tolerance +/- 15 %
Mains fuse protection (slow-blow) 3 x 32 A
Primary continuous power 15,9 kVA
Cos phi 0,99
Efficiency 91 %
Stepless operating current area 0 - 60 A
Operating temperature 0 °C - 40 °C
32 °F - 104 °F
Max. output voltage 300 V
Working voltage 0 - 8 V high resistance
>8 - 300 V
Arc reaction time
1)
7 μs.
Max. output power 10 kW
Duty cycle 100 100 % / 40 °C
Max. output current 60 A
Protection IP 21
Type of cooling AF
Insulation class F
Dimensions (power source with inter-
face) l x w x h
750 x 310 x 700 mm
29.5 x 12.2 x 27.6 in.
Weight 45 kg
99.21 Ib.
Marks of conformity CE
1)
Arc reaction time from detection of overcurrent until the voltage of the cur-
rent connection is switched off (+)