EasyManuals Logo

Fronius Selectiva 4185 Service Manual

Fronius Selectiva 4185
Go to English
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
98
524 Cause: Secondary reference voltage outside the tolerance
Remedy:
- Replace P-control
525 Cause: Current offset
Remedy:
- Replace P-control
526 Cause: Current offset
Remedy:
- Replace P-control
527 Cause: Overcurrent at primary power module
Remedy:
- Check/change secondary diodes
- Replace primary power module
- Replace P-control
529 Cause: No secondary communication available
Remedy:
- Replace P-control
530 Cause: No primary communication available
Remedy:
- Check power module ribbon cable
- Update software version
- Replace P-control
- Replace primary power module
531 Cause: Secondary EEPROM faulty
Remedy:
- Replace P-control
532 Cause: C error
Remedy:
- Update firmware version
- Replace P-control
Status codes in the event of a device fault / control system:
540 Cause: CFM PC board missing/faulty
Remedy:
- Check CFM PC board plug connection
- Replace P-control
- Replace CFM PC board -> contact Technical Support team
541 Cause: No secondary communication
Remedy:
- Replace P-control
542 Cause: Secondary initialisation failed
Remedy:
- Check power module ribbon cable
- Update software version
- Replace P-control
543 Cause: Program/memory fault in characteristic control
Remedy:
- Update firmware version
- Replace P-control

Table of Contents

Other manuals for Fronius Selectiva 4185

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Selectiva 4185 and is the answer not in the manual?

Fronius Selectiva 4185 Specifications

General IconGeneral
BrandFronius
ModelSelectiva 4185
CategoryBattery Charger
LanguageEnglish

Related product manuals